Limit requirements for surface resistance of non-metallic shells of explosion-proof equipment

SINO Testing Services

| 2021-08-02|Return

In hazardous areas with explosive dust or gases, vapors, such as coal powder, flour, aluminum powder, hydrogen gas, etc., static electricity may cause fires or explosions, posing great danger. Therefore, in explosive hazardous areas, the use of insulation materials should be minimized as much as possible. When choosing electrical insulation materials, it is advisable to consider maintaining the minimum insulation resistance to prevent discharge when exposed non-metallic parts come into contact with live parts. For non-metallic insulation materials, the anti-static ability of the equipment can be evaluated by measuring the surface resistance of the equipment casing.



Surface resistance, measured in ohms (Ω), refers to the resistance between two electrodes in contact with a measuring surface.


According to the requirements of IEC60079 series standards:

1. In Class II explosive gas environments, when the surface area of non-metallic enclosures of electrical equipment exceeds a certain limit value (as shown in Table 1), the surface resistance of the non-metallic material needs to be tested and verified to ensure that, by selecting materials, the surface resistance meets at least one of the following requirements when measured according to IEC 60079-0 26.13:
⑴ At ≤ 1 G Ω and (50 ± 5)% relative humidity;

⑵ At ≤ 100 G Ω and (30 ± 5)% relative humidity.



2. In Class III explosive dust environments, if the non-metallic shell surface area of electrical equipment does not exceed 500 square millimeters, the risk of static electricity may not be considered; If the limit is exceeded, surface resistance testing verification is required. The determination requirements are the same as the limit requirements for surface resistance testing in Class II gas environments mentioned above. For fixed installation equipment that cannot meet the surface resistance limit, it can be used toexplosion-proofAdd an "X" after the symbol, add the corresponding warning symbol on the device, and inform the user in the user manual.



Original article, plagiarism and reprinting are strictly prohibited!


Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: xvideos korean | 欧美成人一区免费视频 | 久操中文| 国产无限资源在线观看 | 欧美高清在线精品一区二区不卡 | 午夜精品成人一区二区 | 欧美一级高清片 | 久久久国产精品免费观看 | 亚洲av一级毛片特黄大片 | 日本高清电影在线播放 | 成人三级电影网址 | 欧美一级久久 | 羞羞视频.www在线观看 | 久久久久国产一区二区三区不卡 | 色视频在线观看 | 92精品国产自产在线 | 欧美一区黄色 | 久久影城 | 性爱免费在线视频 | av在线播放地址 | 娇喘在线 | 欧美a久久| av电影手机在线看 | 7m视频成人精品分类 | 免费观看黄视频 | 日本精品久久久一区二区三区 | 成人免费区 | 水多视频在线观看 | 中文字幕偷拍 | 超碰在线97国产 | 亚洲国产精品久久久久婷婷老年 | 欧美一级不卡视频 | 女教师~淫辱の动漫在线 | 羞羞的动漫在线观看 | 久久国产精品久久久久 | 性高湖久久久久久久久aaaaa | 国产亚洲欧美视频 | 国产一区二区三区在线观看视频 | 黄色大片在线观看 | 国产一区免费在线 | 久久99精品久久久久久秒播放器 |